We Export & Ship Worldwide

Wholesale & Retail Sales

ALL DAY LIGHTING & MAINTENANCE SUPPLIES


Home
Incandescent
Incand Reflectors
Halogen
MR16 Reflector
MR11 Reflector
MR8 Reflector
Quartz Heater
PAR Lamps
Compact Fluorescent
CFL Reflectors
Plug-in Fluorescent
4P Plug-in CFL
T12 Fluorescent
T10 Fluorescent
T8 Fluorecent
T6 Fluorescent
 T5 Fluorescent
T2 Fluorescent
 Metal Halide Bulbs
Metal Halide 100-200W
Metal Halide 250-400W
Metal Halide 750-1500W
Merury Vapor
High Pressure Sodium
Low Pressure Sodium
Ceramic HID
Ceramic HID  PAR
SSTV HID Lamps
LED Lamps
LED PAR LAMPS
GE PhotoOptics
Ushio Photo Optics
Osram Photo Optics
Philips Photo/Optics
Medical Lamps
Airfield/Aircraft Lamps
CFL Ballasts
T5/T8/T12 Ballast_
HID Ballasts_
Plumbing
HVAC Supply
Gas Valves
Ignition Module
Furnace Ignitors
WR Gas Valves
HW Zone Valves
Sparcomatic
Fan/Limit Controls
Switching Relay
HW Contactors
Watts Relief Valve
Watts Vent Valve
Ranco Control
WR Temp Control
Agro
Amtrol
A.O.Smith
Copy of A.O.Smith
Bacharach
Beckett
Bar/Colm TAC
Baso
Baso G196  Valve
Baso H15 Valve
Baso H17 Valve
Baso H19 Valve
Baso H43 Valve
Barnes & Jones
Danfoss
Mamac
Reznor
Rheem Parts
Spirotherm
Suntec
Taco
Tjernlund
Lighting Specials
Monthly Specials
Customer Service
Request Quote
 
S8910U Universal Hot Surface Ignition Module
Honeywell #S8910U1000 $94.69 Free Shipping
Genuine Honeywell S8910U Universal Hot Surface Ignition Module replaces existing flame rectification type hot surface ignition modules with the following characteristics: • 120 Vac (up to 5A) HSI elements • Single rod (local sense) or dual rod (remote sense) • One or three ignition trials per call for heat • Four-second or seven-second ignition trials • Prepurge of 32 seconds or less • Up to 96 seconds between trial purge (three-trial mode only) • Natural or LP gas “

S8610U Universal Intermittent Pilot Gas Ignition Control
Honeywell #S8610U1003 $96.69 Free Shipping
Genuine Honeywell S8610S Universal Intermittent Pilot Ignition Module is designed to provide easy field replacement of a wide range of intermittent pilot ignition modules. • Single rod (local sense) or two rod (remote sense)flame sensing,• Non-100 percent shutoff, 100 percent shutoff/lockout, or 100 percent shutoff/continuous retry• Natural or LP gas • Shutoff/lockout times of 15 seconds or longer • Prepurge configurable to 30 seconds or no prepurge • Pilot burners with flow rates of 1,500 Btuh or less
Honeywell #S8610U3009 $107.69 Free Shipping
Genuine Honeywell S8910U Universal Hot Surface Ignition Module replaces existing flame rectification type hot surface ignition modules with the following characteristics:  One or two rod intermittent pilot control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge  Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) intermittent pilot ignition modules # Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed For use with Natural or LP gas  Functional equivalent of S86, S8600, S8610 and S90 modules Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable  Voltage: 24 Volts

   Universal Hot Surface Ignition Module Uni-Kit

Robertshaw #780-910 $99.95 Free Shipping
Genuine Robertshaw 780910 Universal Hot Surface Ignition Module Uni-Kits is designed for use on gas fired systems equipped with a self diagnostic green LED,  Single or three ignition attempts or 7 second ignition trial time, 17 or 34 second ignitor warm up time,  34 seconds or less pre-purge , Used in  Natural or L.P. gas controls,  120 VAC Hot Surface ignitors, Uni-Kit (Replaces most Hot Surface Modules) Features a flame sense circuit
The Uni-Line 712 Series Pilot Ignition System
Robertshaw #712-008 $204.57 Free Shipping
Genuine Robertshaw Universal Intermittent Pilot Ignition System Kit Includes 780-845 (Lockout)Ignition Unit, Gas Valve #720-070 1/2" x 3/4", & LP Regulator, Gas valve has natural gas pressure regulator set at 3.5" WC. A separate L.P. gas pressure regulator set at 11.0" WC is also included. 200,000 Btu Max Nat Gas/320,000 Btu Max LP gas.
The Uni-Line 712 Series Pilot Ignition System
Robertshaw #780-735 $111.47 Free Shipping
Genuine Robertshaw 780-735 Ignition Lockout Model Flame Rectification System. Use with gas valves 7000 BDER and 7100 DER. Has 60 Second Lockout Timing. Control Module, Unit Has 60 Seconds Lockout Timing
*Use With Gas Valve 7000 BDER & 7100 DER


Universal Integrated Module for Silicon Carbide Ignition

White Rodgers #50A55-843 $89.92 Free Shipping  

Genuine White Rodgers Universal Replacement Integrated Ignition Module for Silicon Carbide Applications Used for Gas-Fired Forced-Air Furnaces with Integrated Furnace Control Module with a Silicon Carbide Ignitor  Includes  Diagnostic LED
•Additional Jumpers to Extend the Length of the Connections • Operating Temp -40° To 175°F (-40° To 80°C)

Universal Silicon Carbide Non-Integrated Replacement Module,

White Rodgers #50E47-843 $87.63 Free Shipping

White Rodgers Universal Silicone Carbide Non-Integrated Hot Surface Ignition Module (Integrated) Includes • Program Keys • Mounting Hardware • Double-Sided Foam Back Tape (for ease of installation) • Color-Coded Timing Label • Pre-Printed Hanging Carton, This Unit Replaces 50E47-50, 50E47--60, 50E47-70, 50E47-140, 50E47-150,50E47-160, 50E47-170, 50E47-130